Fifteen cardiac transplant recipients requiring permanent pacing (AAI, n = 9; VVI, n = 6; rate responsive devices, n = 11) for postoperative sinus node (SN) insufficiency underwent evaluation of long-term SN function 240 to 1,461 days after transplantation. The intrinsic rhythm at the time of discharge was sinus in 7 patients; junctional escape in 6 patients; and pacemaker dependent in 2 patients. At follow-up, 5 patients had regained regular sinus rhythm, accounting for a total of 11 patients in sinus rhythm while 4 patients were in junctional bradycardia. The SN recovery time as determined by the permanent pacemaker was normal (< 1,500 msec) in only 1/8 patients in whom it was determined, although 4 of these 8 patients were temporarily overriding the pacemaker during ambulatory monitoring. Patients with pathological SN recovery times included 3 patients with late return of sinus rhythm and 4 patients who had recovered normal sinus rhythm before their discharge from the hospital. Three patients developed late symptoms despite apparent early normalization and underwent delayed pacemaker implantations on postoperative days 35, 52, and 225, respectively. We conclude that, in patients requiring pacemaker implantation after cardiac transplantation, normalization of SN function cannot be inferred from just return of sinus rhythm, regardless of whether it occurs early or late. These findings may have implications when a pacemaker exchange or explantation is being considered.