Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement

J Am Coll Cardiol. 2007 Feb 20;49(7):790-6. doi: 10.1016/j.jacc.2006.10.052. Epub 2007 Feb 5.

Abstract

Objectives: This prospective-randomized study investigated the effect of aortic valve design and patient-prosthesis mismatch (PPM) on coronary flow reserve (CFR) after mechanical or biological aortic valve replacement (AVR) in patients with aortic stenosis (AS).

Background: Coronary flow reserve may be an important parameter of long-term survival after AVR in patients with AS. Reduced CFR may contribute to more cardiovascular events and greater rates of mortality.

Methods: A total of 48 patients undergoing AVR underwent magnetic resonance imaging for the measurement of coronary flow preoperatively, 5 days postoperatively, and at 6-month follow-up with measurement of CFR. Patients scheduled for mechanical AVR were randomized to a tilting disc or bileaflet prosthesis (n = 12 in each group). For biological AVR, patients were scheduled to receive a stented (n = 12) or stentless (n = 12) valve. Patients also underwent echocardiography with measurement of transvalvular pressure gradients and left ventricular mass regression.

Results: Postoperatively, coronary flow increased significantly in all groups (p < 0.001). Only stentless valves demonstrated a normal CFR (3.4 +/- 0.3 vs. 2.3 +/- 0.1 for stented biological valves, 2.1 +/- 0.2 for tilting disc, and 2.2 +/- 0.3 for bileaflet mechanical valves). Patient-prosthesis mismatch with an indexed effective orifice area <0.85 cm2/m2 led to decreased rates of CFR in the tilting disc, stentless, and stented groups. Pressure gradients were 14 +/- 3 mm Hg for tilting disc, 12 +/- 4 mm Hg for bileaflet, 19 +/- 6 mm Hg for stented, and 10 +/- 4 mm Hg for stentless valves.

Conclusions: Normalization of CFR after AVR in patients with AS was observed only for stentless valves. Coronary flow reserve might explain the excellent long-term results for stentless valves. (Impact of Patient-Prosthesis Mismatch on Coronary Flow Reserve; http://www.clinicaltrials.gov/ct/show/NCT00310947?order=1; NCT00310947).

Publication types

  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / surgery*
  • Aortic Valve*
  • Bioprosthesis
  • Blood Pressure
  • Coronary Circulation
  • Female
  • Heart Rate
  • Heart Valve Prosthesis*
  • Heart Ventricles / pathology
  • Humans
  • Male
  • Middle Aged
  • Organ Size
  • Prospective Studies
  • Prosthesis Design
  • Prosthesis Failure
  • Prosthesis Fitting
  • Treatment Outcome
  • Ultrasonography

Associated data

  • ClinicalTrials.gov/NCT00310947