Abstract
We describe a case of obstructive sleep apnea syndrome that occurred after tracheal surgery. The patient refused a tracheal stent placement and any surgical procedure aimed at stabilizing the tracheal walls. She was treated with a continuous positive airway pressure.
MeSH terms
-
Continuous Positive Airway Pressure / methods*
-
Female
-
Humans
-
Laryngostenosis / complications*
-
Laryngostenosis / diagnostic imaging
-
Laryngostenosis / surgery*
-
Middle Aged
-
Postoperative Complications*
-
Sleep Apnea, Obstructive / diagnosis
-
Sleep Apnea, Obstructive / etiology*
-
Sleep Apnea, Obstructive / therapy
-
Tomography, X-Ray Computed
-
Tracheal Stenosis / complications*
-
Tracheal Stenosis / diagnostic imaging
-
Tracheal Stenosis / surgery*
-
Tracheostomy