Sirolimus-eluting stent implantation for treatment of proximal left anterior descending coronary artery lesions: long-term outcome and predictors of adverse cardiac events

Catheter Cardiovasc Interv. 2007 Sep;70(3):368-73. doi: 10.1002/ccd.21127.

Abstract

Objectives: Acute and long-term results after sirolimus-eluting stent (SES) implantation of proximal left anterior descending coronary artery (LAD) disease were evaluated.

Background: Although SES has been used increasingly for the treatment of LAD disease, data regarding their safety and efficacy in a real-world population are limited.

Methods: We investigate the short- and long-term results in 966 patients who underwent SES implantation for stenosis of proximal LAD.

Results: The procedural success rate was 97.6%, and procedural non-Q-wave myocardial infarction (MI) rate was 14.5%. In-hospital major complications occurred in five patients (0.5%), including three deaths and two Q-wave MIs. During follow-up (20.4 +/- 8.9 months), there were 16 deaths (1.7%; 10 cardiac, 6 noncardiac), 2 Q-wave MIs, and 22 target lesion revascularizations (2.3%). Late stent thrombosis occurred in two patients (0.2%), 14 and 23 months after the procedure. The event-free survival rates for cardiac death/Q-wave MI were 98.6% +/- 0.4% at 1 year and 97.8% +/- 0.6% at 2 years. The cumulative probabilities of survival without major adverse cardiac events (MACE) were 96.7% +/- 0.6% at 1 year and 95.4% +/- 0.8% at 2 years. In multivariate analysis, stented length (HR 1.04, 95%CI 1.01-1.07, P = 0.009) and infarct-related artery (HR 5.18, 95%CI 1.09-24.64, P = 0.039) were independently related to cardiac death/Q-wave MI. In addition, stented length (HR 1.04, 95%CI 1.02-1.06, P < 0.001) and left ventricular dysfunction (HR 2.66, 95%CI 1.07-6.63, P = 0.036) were significant independent predictors of MACE.

Conclusions: SES implantation for proximal LAD disease appears safe and effective in a real-world population, and the independent predictors of MACE included stented length and left ventricular dysfunction.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Coated Materials, Biocompatible*
  • Coronary Angiography
  • Coronary Disease / diagnostic imaging
  • Coronary Disease / surgery*
  • Electrocardiography
  • Female
  • Follow-Up Studies
  • Humans
  • Immunosuppressive Agents / pharmacology*
  • Male
  • Middle Aged
  • Myocardial Revascularization / methods*
  • Postoperative Complications
  • Prognosis
  • Retrospective Studies
  • Sirolimus / pharmacology*
  • Stents*
  • Time Factors

Substances

  • Coated Materials, Biocompatible
  • Immunosuppressive Agents
  • Sirolimus