Quantitative assessment of range fluctuations in charged particle lung irradiation

Int J Radiat Oncol Biol Phys. 2008 Jan 1;70(1):253-61. doi: 10.1016/j.ijrobp.2007.08.049. Epub 2007 Oct 29.

Abstract

Purpose: Water equivalent path length (WEL) variations due to respiration can change the range of a charged particle beam and result in beam overshoot to critical organs or beam undershoot to tumor. We have studied range fluctuations by analyzing four-dimensional computed tomography data and quantitatively assessing potential beam overshoot.

Methods and materials: The maximal intensity volume is calculated by combining the gross tumor volume contours at each respiratory phase in the four-dimensional computed tomography study. The first target volume calculates the maximal intensity volume for the entire respiratory cycle (internal target volume [ITV]-radiotherapy [RT]), and the second target volume is the maximal intensity volume corresponding to gated RT (gated-RT, approximately 30% phase window around exhalation). A compensator at each respiratory phase is calculated. Two "composite" compensators for ITV-RT and gated-RT are then designed by selecting the minimal compensator depth at the respective respiratory phase. These compensators are then applied to the four-dimensional computed tomography data to estimate beam penetration. Analysis metrics include range fluctuation and overshoot volume, both as a function of gantry angle. We compared WEL fluctuations observed in treating the ITV-RT versus gated-RT in 11 lung patients.

Results: The WEL fluctuations were <21.8 mm-WEL and 9.5 mm-WEL for ITV-RT and gated-RT, respectively for all patients. Gated-RT reduced the beam overshoot volume by approximately a factor of four compared with ITV-RT. Such range fluctuations can affect the efficacy of treatment and result in an excessive dose to a distal critical organ.

Conclusion: Time varying range fluctuation analysis provides information useful for determining appropriate patient-specific treatment parameters in charged particle RT. This analysis can also be useful for optimizing planning and delivery.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Aged
  • Aged, 80 and over
  • Carcinoma, Large Cell / pathology
  • Carcinoma, Large Cell / radiotherapy
  • Carcinoma, Non-Small-Cell Lung / pathology
  • Carcinoma, Non-Small-Cell Lung / radiotherapy
  • Exhalation
  • Female
  • Humans
  • Lung
  • Lung Neoplasms / pathology
  • Lung Neoplasms / radiotherapy*
  • Male
  • Middle Aged
  • Movement*
  • Radiotherapy Planning, Computer-Assisted / methods
  • Radiotherapy, Conformal / instrumentation
  • Radiotherapy, Conformal / methods*
  • Respiration*
  • Tomography, X-Ray Computed / methods*
  • Tumor Burden