Objective: To review the spot protein:creatinine ratio and albumin:creatinine ratio as diagnostic tests for significant proteinuria in hypertensive pregnant women.
Design: Systematic review.
Data sources: Medline and Embase, the Cochrane Library, reference lists, and experts. Review methods Literature search (1980-2007) for articles of the spot protein:creatinine ratio or albumin:creatinine ratio in hypertensive pregnancy, with 24 hour proteinuria as the comparator.
Results: 13 studies concerned the spot protein:creatinine ratio (1214 women with primarily gestational hypertension). Nine studies reported sensitivity and specificity for eight cut-off points, median 24 mg/mmol (range 17-57 mg/mmol; 0.15-0.50 mg/mg). Laboratory assays were not well described. Diagnostic test characteristics were recalculated for a cut-off point of 30 mg/mmol. No significant heterogeneity in cut-off points was found between studies over a range of proteinuria. Pooled values gave a sensitivity of 83.6% (95% confidence interval 77.5% to 89.7%), specificity of 76.3% (72.6% to 80.0%), positive likelihood ratio of 3.53 (2.83 to 4.49), and negative likelihood ratio of 0.21 (0.13 to 0.31) (nine studies, 1003 women). Two studies of the spot albumin:creatinine ratio (225 women) found optimal cut-off points of 2 mg/mmol for proteinuria of 0.3 g/day or more and 27 mg/mmol for albuminuria.
Conclusion: The spot protein:creatinine ratio is a reasonable "rule-out" test for detecting proteinuria of 0.3 g/day or more in hypertensive pregnancy. Information on use of the albumin:creatinine ratio in these women is insufficient.