An improved method for the quantification of left-to-right cardiac shunts

J Nucl Med. 1991 Sep;32(9):1808-12.

Abstract

We have investigated a technique for quantifying QP/QS in left-to-right cardiac shunts. In this method, the gamma variate, which is fitted to the first-pass portion of the lung curve, is used to generate a curve, which simulates the response of a normal lung curve with systemic recirculation. The difference between this curve and the observed lung curve is then used to calculate QP/QS. This method was evaluated on a set of simulated lung time-activity curves with precisely known QP/QS values on a group of 11 patients with no clinical suspicion of cardiac shunt and on a group of 30 patients referred for cardiac shunt studies. The QP/QS in each of these studies was determined by three individuals using both the Maltz-Treves method and the new method. This method yielded QP/QS values that were more accurate on the simulated lung data and had less interobserver variation on all the studies than those obtained from the Maltz-Treves method.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Female
  • Heart Septal Defects / diagnostic imaging*
  • Humans
  • Male
  • Middle Aged
  • Radionuclide Imaging
  • Technetium Tc 99m Pentetate*

Substances

  • Technetium Tc 99m Pentetate