Conspicuity of zones of ablation after radiofrequency ablation in porcine livers: comparison of an extracellular and an SPIO contrast agent

J Magn Reson Imaging. 2008 Jul;28(1):263-70. doi: 10.1002/jmri.21423.

Abstract

Purpose: To compare conspicuity of zones of ablation on nonenhanced, gadopentetate dimeglumine-(Gd-DTPA) and ferucarbotran-(SPIO)-enhanced magnetic resonance (MR) images.

Materials and methods: In all, 33 radiofrequency ablations (RFA) were performed in 17 healthy porcine livers at 1.5T MR imaging 1 day and 2 and 4 weeks after RFA: T2-weighted (w) ultra turbo spin echo (UTSE), proton density (PD)-w UTSE, T1-w gradient echo (GRE) pre- and 5 minutes postcontrast administration, dynamic T1-w GRE during Gd-DTPA (Magnevist) or SPIO (Resovist) administration, T2-w UTSE, and PD-w UTSE sequences 10 minutes after SPIO administration. Regions of interest (ROIs) for contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were drawn in consensus by two radiologists.

Results: PD-w SPIO-enhanced images (23.5 +/- 5.5) showed higher liver-to-lesion CNR than T1-w GRE Gd-DTPA-enhanced images (13.5 +/- 6.1) 1 day after RFA (P < or = 0.05). At all other timepoints, liver-to-lesion CNR of PD-w and T2-w SPIO-enhanced images did not differ significantly from T1-w GRE Gd-DTPA-enhanced images (P > or = 0.05). Nonenhanced T2-w images revealed lower liver-to-lesion CNR (7.0 +/- 7.5/6.5 +/- 5.9/6.8 +/- 5.0, 1 day/2 weeks/4 weeks, respectively) than T2-w SPIO-enhanced (17.4 +/- 4.8/15.3 +/- 4.5/14.2 +/- 5.7), PD-w SPIO-enhanced (23.5 +/- 5.5/16.9 +/- 3.6, 1 day/2 weeks), and T1-w Gd-DTPA-enhanced (15.3 +/- 3.6/12.7 +/- 3.5, 2/4 weeks) images (P < or = 0.05). Liver-to-lesion CNR of SPIO-enhanced dynamic T1-w GRE images after 30, 80, 150, and 240 seconds did not change significantly over time (P > or = 0.05).

Conclusion: One day after RFA lesion conspicuity on PD-w ferucarbotran-enhanced images is better than on T1-w GRE Gd-DTPA-enhanced images. At all other timepoints, ferucarbotran is not superior to gadolinium. Ferucarbotran- and gadolinium-enhanced images improve lesion conspicuity compared with nonenhanced T2-w images at all timepoints.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Catheter Ablation*
  • Contrast Media*
  • Dextrans
  • Ferrosoferric Oxide
  • Gadolinium DTPA
  • Image Enhancement
  • Iron
  • Liver / pathology*
  • Magnetic Resonance Imaging / methods*
  • Magnetite Nanoparticles
  • Oxides
  • Swine

Substances

  • Contrast Media
  • Dextrans
  • Magnetite Nanoparticles
  • Oxides
  • Iron
  • ferumoxides
  • Gadolinium DTPA
  • Ferrosoferric Oxide