Comparison of spectral-domain versus time-domain optical coherence tomography in management of age-related macular degeneration with ranibizumab

Ophthalmology. 2009 May;116(5):947-55. doi: 10.1016/j.ophtha.2008.11.002. Epub 2009 Feb 20.

Abstract

Purpose: To compare the ability to delineate and detect patterns of choroidal neovascularization (CNV) activity in patients with exudative age-related macular degeneration (AMD) after ranibizumab treatment between time-domain optical coherence tomography (TD-OCT) and 4 different spectral-domain optical coherence tomography (SD-OCT) devices.

Design: Prospective, consecutive case series.

Participants: Sixty-one eyes of 58 patients with exudative AMD after ranibizumab treatment were included in this study.

Methods: All patients were imaged with TD-OCT and at least 1 of 4 different SD-OCT devices at the same visit after ranibizumab treatment. The OCT images were analyzed in a masked fashion by 2 independent graders (KS, TY) to delineate and detect the presence of CNV activity defined as the presence of subretinal fluid, intraretinal cysts, intraretinal fluid, sub-retinal pigment epithelium (sub-RPE) fluid, or a combination thereof. The automated evaluation of retinal thickness also was analyzed between devices.

Main outcome measures: Evidence of CNV activity on linear B-scans and 3-dimensional so-called cube scans on SD-OCT and linear B-scan on TD-OCT.

Results: In linear B-scan mode, all 4 SD-OCT devices were superior in their ability to delineate sub-RPE fluid compared with TD-OCT (P<0.05). Three of 4 SD-OCT devices were superior in delineating intraretinal fluid, and 2 of 4 SD-OCT devices were superior in delineating subretinal fluid and intraretinal cysts (P<0.05). In the 3-dimensional so-called cube mode, all 4 SD-OCT devices were superior in detecting subretinal fluid and 2 of 4 SD-OCT devices were superior in detecting sub-RPE and intraretinal fluid (P<0.05). There were significant correlations in center point thickness between all SD-OCT devices and TD-OCT (P<0.01), and 3 of 4 and 1 of 3 SD-OCT devices showed significant differences from TD-OCT in center point thickness (P<0.01) and center subfield thickness (P<0.001), respectively.

Conclusions: SD-OCT is superior to TD-OCT in evaluating for CNV activity in patients with wet AMD after ranibizumab injection. Retinal thickness measurements between SD-OCT and TD-OCT also were significantly different.

Financial disclosure(s): Proprietary or commercial disclosure may be found after the references.

Publication types

  • Case Reports
  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Angiogenesis Inhibitors / therapeutic use*
  • Antibodies, Monoclonal / therapeutic use*
  • Antibodies, Monoclonal, Humanized
  • Choroidal Neovascularization / diagnosis*
  • Choroidal Neovascularization / drug therapy
  • Exudates and Transudates
  • Female
  • Humans
  • Macular Degeneration / diagnosis*
  • Macular Degeneration / drug therapy
  • Male
  • Prospective Studies
  • Ranibizumab
  • Retina / pathology
  • Tomography, Optical Coherence / methods*

Substances

  • Angiogenesis Inhibitors
  • Antibodies, Monoclonal
  • Antibodies, Monoclonal, Humanized
  • Ranibizumab