64-Slice CT angiography of the abdominal aorta and abdominal arteries: comparison of the diagnostic efficacy of iobitridol 350 mgI/ml versus iomeprol 400 mgI/ml in a prospective, randomised, double-blind multi-centre trial

Eur Radiol. 2010 Mar;20(3):572-83. doi: 10.1007/s00330-009-1600-6. Epub 2009 Sep 30.

Abstract

Purpose: The purpose of this study was to assess the influence of iodine concentration on diagnostic efficacy in multi-detector-row computed tomography (MDCT) angiography of the abdominal aorta and abdominal arteries.

Methods: IRB approval and informed consent were obtained. In this double-blind trial, patients were randomised to undergo MDCT angiography of the abdominal arteries during administration of iobitridol (350 mgI/ml) or iomeprol (400 mgI/ml). Each centre applied its own technique for delivery of contrast medium, regardless of iodine concentration. Diagnostic efficacy, image quality, visualisation of the arterial wall and arterial enhancement were evaluated. A total of 153 patients received iobitridol and 154 received iomeprol.

Results: The ability to reach a diagnosis was "satisfactory" to "totally satisfactory" in 152 (99.3%) and 153 (99.4%) patients respectively. Image quality was rated as being "good" to "excellent" in 94.7 and 94.8% segments respectively. Similar results were observed for image quality of arterial walls (84.3 vs. 83.2%). The mean relative changes in arterial enhancement between baseline and arterial phase images showed no statistically significant differences.

Conclusion: This study demonstrated the non-inferiority of the 350 versus 400 mgI/ml iodine concentration, in terms of diagnostic efficacy, in abdominal MDCT angiography. It also confirmed the high robustness and reliability of this technique across multi-national practices.

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Angiography / methods*
  • Aorta, Abdominal / diagnostic imaging*
  • Contrast Media
  • Dose-Response Relationship, Drug
  • Double-Blind Method
  • Europe
  • Female
  • Humans
  • Image Enhancement / methods*
  • Iohexol / administration & dosage
  • Iohexol / analogs & derivatives*
  • Iopamidol / administration & dosage
  • Iopamidol / analogs & derivatives*
  • Male
  • Prospective Studies
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*

Substances

  • Contrast Media
  • iomeprol
  • iobitridol
  • Iohexol
  • Iopamidol