Hybrid of opposite-contrast magnetic resonance angiography of the brain by combining time-of-flight and black blood sequences: its value in moyamoya disease

J Comput Assist Tomogr. 2010 Mar-Apr;34(2):242-6. doi: 10.1097/RCT.0b013e3181b8aff4.

Abstract

Objective: We assessed the value of a new magnetic resonance angiography (MRA) technique named hybrid of opposite-contrast (HOP) MRA in the diagnosis of moyamoya disease.

Methods: Using a dual-echo sequence, we obtained the first echo for time-of-flight (TOF) MRA followed by the second echo for black blood MRA. We then subtracted the black blood MRA data set from that of the TOF MRA followed by maximum-intensity projection. In 14 patients, we performed HOP MRA and compared the findings with those on 3-dimensional TOF MRA and MR images. The HOP MRA was also compared with a radionuclide perfusion study (7 patients).

Results: The HOP MRA technique improved the demonstration of distal arteries in 13 patients. The findings in HOP MRA correlated with MR images in 9 patients as well as with the perfusion study in 6 patients.

Conclusions: The HOP MRA technique demonstrated the distal arterial branches in moyamoya disease well and facilitated the perfusion assessment with MR imaging.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Brain / blood supply*
  • Child
  • Diagnosis, Differential
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted
  • Imaging, Three-Dimensional
  • Magnetic Resonance Angiography / methods*
  • Male
  • Middle Aged
  • Moyamoya Disease / diagnosis*
  • Moyamoya Disease / diagnostic imaging
  • Tomography, Emission-Computed, Single-Photon