Virtual angioscopy and 3D navigation: a new technique for analysis of the aortic arch after vascular surgery

Eur J Vasc Endovasc Surg. 2010 Sep;40(3):340-7. doi: 10.1016/j.ejvs.2010.05.019. Epub 2010 Jul 8.

Abstract

Purpose: Anatomy of the aortic arch is highly variable and can be drastically altered by surgical or endovascular procedures. Detailed analysis of computed tomography (CT) scans is facilitated by reconstruction techniques such as virtual angioscopy (VA). In the present study, we have evaluated the benefit of VA for the assessment of aortic arch abnormalities in patients with prior surgical or endovascular procedures.

Material and methods: We analysed post-procedural CT scans available in 103 patients who underwent thoracic aortic procedures between 2006 and 2009 at our institution. Patients were classified into three groups: surgical (group A, n = 26), hybrid (group B, n = 27) and endovascular (group C, n = 50), procedures. A 64 LightSpeed volume computed tomography (VCT) multidetector-row computed tomography was used, allowing maximal intensity projection, maximal projection rendering imaging and three-dimensional (3D) rendering of images. VA reconstruction was performed by applying volume-rendered thresholds and spatial rendering to generate endoluminal views.

Results: Multiplanar reformations (MPRs) detected 46 abnormalities in 39 patients: inadequate apposition of the proximal rim of a stent-graft (n = 21), abnormalities of the stent-graft itself (n = 11), aortic aneurysm (n = 6), residual intimal tears (n = 5) and secondary dissection (n = 3). VA provided additional information in 76% of cases (35/46) and was more contributive after endovascular repair than after open repair (group A: 54% (7/14), group B: 75% (9/12), group C: 95% (19/20)). VA improved localisation of abnormalities with respect to supra-aortic vessels, measured inadequate stent-graft apposition in relation to the aortic wall and precisely analysed kinking or inadequate apposition of overlapping stent grafts. VA diagnosed three additional abnormalities: two false aneurysms and one retrograde dissection developed on a suture line.

Conclusions: VA conceptualises planar images by 3D reconstruction. It provides additional information in comparison with conventional CT scans by allowing precise localisation of abnormalities with respect to the aortic wall itself and supra-aortic vessels. Furthermore, it facilitates analysis of abnormalities in case of overlapping stent grafts.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Angioscopy*
  • Aorta, Thoracic / diagnostic imaging*
  • Aorta, Thoracic / surgery*
  • Aortic Diseases / diagnostic imaging*
  • Aortic Diseases / surgery*
  • Aortography / methods
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Female
  • Humans
  • Imaging, Three-Dimensional*
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Radiographic Image Interpretation, Computer-Assisted*
  • Reoperation
  • Retrospective Studies
  • Stents
  • Tomography, X-Ray Computed*
  • Treatment Outcome