Comparison of subcutaneous connective tissue responses among three different formulations of gutta-percha used in thermatic techniques

Int Endod J. 1990 Jul;23(4):211-7. doi: 10.1111/j.1365-2591.1990.tb00102.x.

Abstract

A study of the subcutaneous connective tissue response of 24 white rats to three different formulations of gutta-percha was undertaken. The prepared specimens were examined under the light microscope after intervals of 7, 21, 60 and 120 days. The results showed identical tissue responses after the initial period of 7 days. However, after 120 days the gutta-percha supplied with the Ultrafil system presented mature granulation tissue with neither oedema nor vascular congestion, in contrast to the responses observed with the McSpadden and Obtura formulations.

Publication types

  • Comparative Study

MeSH terms

  • Animals
  • Biocompatible Materials
  • Connective Tissue / drug effects
  • Gutta-Percha / chemistry
  • Gutta-Percha / toxicity*
  • Inflammation / chemically induced
  • Rats

Substances

  • Biocompatible Materials
  • Gutta-Percha