Usefulness of TEE as the primary imaging technique to guide transcatheter transapical aortic valve implantation

JACC Cardiovasc Imaging. 2011 Feb;4(2):115-24. doi: 10.1016/j.jcmg.2010.10.009.

Abstract

Objectives: The aim of this study was to: 1) determine the usefulness of transesophageal echocardiography (TEE) as the primary technique to guide transapical (TA) transcatheter aortic valve implantation (TAVI); and 2) to compare TEE with angiography as the primary imaging modality for TA-TAVI guidance.

Background: TEE has been routinely used as an adjunct to angiography during TA-TAVI procedures, but very few data exist on the use of TEE as the primary imaging technique guiding TA-TAVI.

Methods: One hundred consecutive high-risk patients (mean age 79 ± 9 years, mean logistic EuroSCORE: 25.8 ± 17.6%) who underwent TA-TAVI in our center were included. The Edwards valve was used in all cases, and all procedures were performed in an operating room without hybrid facilities. The TA-TAVI was primarily guided by angiography in the first 25 patients (A-TAVI group) and by TEE in the last 75 patients (TEE-TAVI group). Procedural, 30-day, and follow-up results were evaluated.

Results: No differences were observed between groups at baseline except for a higher (p = 0.001) prevalence of moderate or severe mitral regurgitation in the TEE-TAVI group. The procedure was successful in 97.3% and 100% of the patients in the TEE-TAVI and A-TAVI groups, respectively (p = 1.0), and a lower contrast volume was used in the TEE-TAVI group (12 [5 to 20] ml vs. 40 [20 to 50] ml, p < 0.0001). There were no differences between groups in the occurrence of valve malposition needing a second valve (TEE-TAVI: 5.3%; A-TAVI: 4%; p = 1.0) or valve embolization (TEE-TAVI: 1.3%; A-TAVI: 4%; p = 0.44). The results regarding post-procedural valve hemodynamic status and aortic regurgitation were similar between groups. The survival rates at 30-day and 1-year follow-up were 87% and 75% in the TEE-group and 88% and 84% in the A-TAVI group, respectively (log-rank = 0.49).

Conclusions: TEE-TAVI was associated with similar acute and midterm results as A-TAVI and significantly reduced contrast media use during the procedures. These results suggest the feasibility and safety of performing TA-TAVI procedures in an operating room without hybrid facilities, but larger studies are needed to confirm these findings.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / therapy*
  • Cardiac Catheterization* / adverse effects
  • Cardiac Catheterization* / instrumentation
  • Cardiac Catheterization* / mortality
  • Chi-Square Distribution
  • Contrast Media
  • Echocardiography, Transesophageal*
  • Feasibility Studies
  • Female
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis Implantation / mortality
  • Humans
  • Kaplan-Meier Estimate
  • Logistic Models
  • Male
  • Prosthesis Design
  • Quebec
  • Radiography, Interventional*
  • Risk Assessment
  • Risk Factors
  • Severity of Illness Index
  • Time Factors
  • Treatment Outcome
  • Ultrasonography, Interventional*

Substances

  • Contrast Media