Contrast-enhanced MR angiography of the abdomen with highly accelerated acquisition techniques

Radiology. 2011 Nov;261(2):587-97. doi: 10.1148/radiol.11110242. Epub 2011 Sep 7.

Abstract

Purpose: To demonstrate that highly accelerated (net acceleration factor [R(net)] ≥ 10) acquisition techniques can be used to generate three-dimensional (3D) subsecond timing images, as well as diagnostic-quality high-spatial-resolution contrast material-enhanced (CE) renal magnetic resonance (MR) angiograms with a single split dose of contrast material.

Materials and methods: All studies were approved by the institutional review board and were HIPAA compliant; written consent was obtained from all participants. Twenty-two studies were performed in 10 female volunteers (average age, 47 years; range, 27-62 years) and six patients with renovascular disease (three women; average age, 48 years; range, 37-68 years; three men; average age, 60 years; range, 50-67 years; composite average age, 54 years; range, 38-68 years). The two-part protocol consisted of a low-dose (2 mL contrast material) 3D timing image with approximate 1-second frame time, followed by a high-spatial-resolution (1.0-1.6-mm isotropic voxels) breath-hold 3D renal MR angiogram (18 mL) over the full abdominal field of view. Both acquisitions used two-dimensional (2D) sensitivity encoding acceleration factor (R) of eight and 2D homodyne (HD) acceleration (R(HD)) of 1.4-1.8 for R(net) = R · R(HD) of 10 or higher. Statistical analysis included determination of mean values and standard deviations of image quality scores performed by two experienced reviewers with use of eight evaluation criteria.

Results: The 2-mL 3D time-resolved image successfully portrayed progressive arterial filling in all 22 studies and provided an anatomic overview of the vasculature. Successful timing was also demonstrated in that the renal MR angiogram showed adequate or excellent portrayal of the main renal arteries in 21 of 22 studies.

Conclusion: Two-dimensional acceleration techniques with R(net) of 10 or higher can be used in CE MR angiography to acquire (a) a 3D image series with 1-second frame time, allowing accurate bolus timing, and (b) a high-spatial-resolution renal angiogram.

Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11110242/-/DC1.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Adult
  • Aged
  • Case-Control Studies
  • Contrast Media* / administration & dosage
  • Female
  • Humans
  • Image Enhancement / methods*
  • Imaging, Three-Dimensional / instrumentation
  • Imaging, Three-Dimensional / methods
  • Kidney Diseases / diagnosis*
  • Magnetic Resonance Angiography / instrumentation
  • Magnetic Resonance Angiography / methods*
  • Male
  • Meglumine / administration & dosage
  • Meglumine / analogs & derivatives*
  • Middle Aged
  • Organometallic Compounds* / administration & dosage
  • Renal Circulation

Substances

  • Contrast Media
  • Organometallic Compounds
  • gadobenic acid
  • Meglumine