Quantification of PCDD/Fs and dioxin-like PCBs in small amounts of human serum using the sensitive H1L7.5c1 mouse hepatoma cell line: optimization and analysis of human serum samples from adolescents of the Flemish human biomonitoring program FLEHS II

Talanta. 2011 Oct 15;85(5):2484-91. doi: 10.1016/j.talanta.2011.07.103. Epub 2011 Aug 5.

Abstract

Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast and inexpensive tool for the throughput analysis of dioxin-like compounds in a large number of samples and requires only small sample volumes, the use of this technique in human biomonitoring programs provides a good alternative to GC-HRMS. In this study, a method for the separate analysis of PCDD/Fs and dioxin-like PCBs (dl-PCBs) in human serum with the new sensitive H1L7.5c1 mouse hepatoma cell line was optimized. Sample dilution factors of 5 and 2.4 were selected for routine analysis of respectively the PCDD/Fs and dl-PCBs. The validation studies showed that repeatability and within-lab reproducibility for the quality control (QC) standard were within the in-house criteria. A long-term within-lab reproducibility of 25% for the PCDD/F fraction and 41% for the dl-PCB fraction for the analysis of pooled serum samples, expressed as pg BEQ/g fat, was determined. CALUX recoveries of the spiked procedural blanks were within the acceptable in-house limits of 80-120% for both fractions and the LOQ was 30.3 pg BEQ/g fat for the PCDD/Fs and 14.5 pg BEQ/g fat for the dl-PCBs. The GC-HRMS recovery of a C13-spiked pooled serum sample was between 60 and 90% for all PCDD/F congeners and between 67 and 82% for the non-ortho PCBs. An adequate separation between both fractions was found. The CALUX/GC-HRMS ratio for a pooled serum sample was respectively 2.0 and 1.4 for the PCDD/Fs and the dl-PCBs, indicating the presence of additional AhR active compounds. As expected, a correlation was found between human serum samples analyzed with both the new H1L7.5c1 cell line and the more established H1L6.1c3 cell line. The geometric mean CALUX-BEQ values, reported for the adolescents of the second Flemish Environment and Health Study (FLEHS II) recruited in 2009-2010, were 108 (95% CI: 101-114) pg CALUX-BEQ/g fat for the PCDD/Fs and 32.1 (30.1-34.2) pg CALUX-BEQ/g fat for the dioxin-like PCBs.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Animals
  • Belgium
  • Benzofurans / analysis*
  • Benzofurans / blood
  • Cell Line, Tumor
  • Dibenzofurans, Polychlorinated
  • Dose-Response Relationship, Drug
  • Gas Chromatography-Mass Spectrometry
  • Humans
  • Limit of Detection
  • Liver Neoplasms, Experimental / chemistry*
  • Liver Neoplasms, Experimental / pathology
  • Mice
  • Polychlorinated Biphenyls / analysis*
  • Polychlorinated Biphenyls / blood
  • Polychlorinated Dibenzodioxins / analogs & derivatives*
  • Polychlorinated Dibenzodioxins / analysis
  • Polychlorinated Dibenzodioxins / blood
  • Reproducibility of Results

Substances

  • Benzofurans
  • Dibenzofurans, Polychlorinated
  • Polychlorinated Dibenzodioxins
  • Polychlorinated Biphenyls