Glucose sensor excludes hypoglycaemia as cause of death

Diabetes Res Clin Pract. 2012 May;96(2):e30-2. doi: 10.1016/j.diabres.2012.01.019. Epub 2012 Feb 2.

Abstract

The cause of death can be difficult to verify post-mortem in unexpected deaths in patients with Type 1 diabetes. This report describes an unexpected death in a 44-year-old man with Type 1 diabetes treated with sensor-augmented pump therapy. Continuous glucose monitoring data proved useful in determining the cause of death.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Blood Glucose Self-Monitoring*
  • Cause of Death*
  • Diabetes Mellitus, Type 1 / complications*
  • Fatal Outcome
  • Humans
  • Hypoglycemia / complications*
  • Male