Abstract

Introduction and objectives: Measurement of natriuretic peptides may be recommended prior to echocardiography in patients with suspected heart failure. Cut-off point for heart failure diagnosis in primary care is not well established. We aimed to assess the optimal diagnostic cut-off value of N-terminal pro-B-type natriuretic peptide on a community population attended in primary care.

Methods: Prospective diagnostic accuracy study of a rapid point-of-care N-terminal pro-B-type natriuretic peptide test in a primary healthcare centre. Consecutive patients referred by their general practitioners to echocardiography due to suspected heart failure were included. Clinical history and physical examination based on Framingham criteria, electrocardiogram, chest X-ray, N-terminal pro-B-type natriuretic peptide measurement and echocardiogram were performed. Heart failure diagnosis was made by a cardiologist blinded to N-terminal pro-B-type natriuretic peptide value, using the European Society of Cardiology diagnosis criteria (clinical and echocardiographic data).

Results: Of 220 patients evaluated (65.5% women; median 74 years [interquartile range 67-81]). Heart failure diagnosis was confirmed in 52 patients (23.6%), 16 (30.8%) with left ventricular ejection fraction <50% (39.6 [5.1]%). Median values of N-terminal pro-B-type natriuretic peptide were 715 pg/mL [interquartile range 510.5-1575] and 77.5 pg/mL [interquartile range 58-179.75] for patients with and without heart failure respectively. The best cut-off point was 280 pg/mL, with a receiver operating characteristic curve of 0.94 (95% confidence interval, 0.91-0.97). Six patients with heart failure diagnosis (11.5%) had N-terminal pro-B-type natriuretic peptide values <400 pg/mL. Measurement of natriuretic peptides would avoid 67% of requested echocardiograms.

Conclusions: In a community population attended in primary care, the best cut-off point of N-terminal pro-B-type natriuretic peptide to rule out heart failure was 280 pg/mL. N-terminal pro-B-type natriuretic peptide measurement improve work-out diagnoses and could be cost-effectiveness.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Area Under Curve
  • Comorbidity
  • Confidence Intervals
  • Cost-Benefit Analysis
  • Echocardiography, Doppler
  • Electrocardiography
  • Female
  • Heart Failure / blood
  • Heart Failure / diagnosis*
  • Heart Failure / drug therapy
  • Humans
  • Male
  • Natriuretic Peptide, Brain / blood*
  • Peptide Fragments / blood*
  • Point-of-Care Systems / economics
  • Predictive Value of Tests
  • Primary Health Care
  • ROC Curve
  • Ventricular Dysfunction / diagnosis

Substances

  • Peptide Fragments
  • pro-brain natriuretic peptide (1-76)
  • Natriuretic Peptide, Brain