High-resolution 3D scar imaging using a novel late iodine enhancement multidetector CT protocol to guide ventricular tachycardia catheter ablation

J Cardiovasc Electrophysiol. 2013 Jun;24(6):708-10. doi: 10.1111/jce.12047. Epub 2012 Dec 7.

Abstract

Scar delineation with late gadolinium-enhanced MRI can direct VT substrate mapping and ablation, but imaging is poor and relatively contraindicated in the majority of patients with ICDs. We present a case of scar definition using late iodine-enhanced multidetector CT in a patient with ischemic cardiomyopathy and multiple ICD shocks for VT. CT images were acquired using a novel intracoronary contrast delivery protocol which provided high-resolution subendocardial scar visualization. The segmented scar images were subsequently imported into an electroanatomic mapping platform to guide successful VT ablation.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Catheter Ablation*
  • Cicatrix / pathology
  • Humans
  • Iodine
  • Male
  • Multidetector Computed Tomography / methods*
  • Myocardium / pathology*
  • Tachycardia, Ventricular / pathology*
  • Tachycardia, Ventricular / surgery*

Substances

  • Iodine