Context: Rapid onsite adequacy assessment is stated to improve the diagnostic performance of EUS-FNA.
Objectives: The aim of this study was to establish if the introduction of adequacy assessment performed by a biomedical scientist (cytotechnologist) to an established EUS service improved the diagnostic accuracy of EUS guided FNA of solid pancreaticobiliary lesions.
Design and patients: This retrospective study includes all patients with solid pancreaticobiliary lesions who underwent EUS-FNA from April 2009 to September 2010. An in room cytotechnologist was present for 2 out of the 4 weekly EUS lists and therefore there were two groups identified: Group 1, cytotechnologist absent; and Group 2, cytotechnologist present.
Results: There were 82 patients in Group 1 and 97 patients in Group 2. There was no statistically significant difference in the number of passes (4.1 vs. 4.3), the inadequate aspirate rate (7.3% vs. 5.1%) or the mean size of the lesions (34.7 vs. 32.6 mm) between the groups. The accuracy, sensitivity, specificity, positive predictive value and negative predictive value in Group 1 were 89%, 88%, 100%, 100% and 50% respectively. The results in Group 2 were 91%, 90%, 100%, 100% and 69% respectively. There was no statistically significant difference between the two groups.
Conclusions: In this study the adequacy assessment performed by a cytotechnologist did not improve the diagnostic accuracy of EUS-FNA. In an established EUS-FNA service with low inadequate aspirate rates, onsite adequacy assessment may not improve results of the test.