Influence of transcatheter aortic valve replacement strategy and valve design on stroke after transcatheter aortic valve replacement: a meta-analysis and systematic review of literature

J Am Coll Cardiol. 2014 May 27;63(20):2101-2110. doi: 10.1016/j.jacc.2014.02.540. Epub 2014 Mar 13.

Abstract

Objectives: The study undertook a systematic review to establish and compare the risk of stroke between the 2 widely used approaches (transfemoral [TF] vs. transapical [TA]) and valve designs (CoreValve, Medtronic, Minneapolis, Minnesota vs. Edwards Valve, Edwards Lifesciences, Irvine, California) for transcatheter aortic valve replacement (TAVR).

Background: There has been a rapid adoption and expansion in the use of TAVR. The technique is however far from perfect and requires further refinement to alleviate safety concerns that include stroke.

Methods: All studies reporting on the risk of stroke after TAVR were identified using an electronic search and pooled using established meta-analytical guidelines.

Results: 25 multicenter registries and 33 single-center studies were included in the analysis. There was no difference in pooled 30-day stroke post-TAVR between the TF and TA approach in multicenter (2.8% [95% confidence interval (CI): 2.4 to 3.4] vs. 2.8% [95% CI: 2.0 to 3.9]) and single-center studies (3.8% [95% CI: 3.1 to 4.6] vs. 3.4% [95% CI: 2.5 to 4.5]). Similarly, there was no difference in pooled 30-day stroke post TAVR between the CoreValve and Edwards Valve in multicenter (2.4% [95% CI: 1.9 to 3.2] vs. 3.0% [95% CI: 2.4 to 3.7]) and single-center studies (3.8% [95% CI: 2.8 to 4.9] vs. 3.2% [95% CI: 2.4 to 4.3]). There was a decline in stroke risk with experience and technological advancement. There was no difference in the outcome of 30-day stroke between TAVR and surgical aortic valve replacement.

Conclusions: Our findings suggest that the risk of 30-day stroke after TAVR is similar between the approaches and valve types. There has been a decline in stroke risk after TAVR with improvements in valve technology, patient selection, and operator experience.

Keywords: CoreValve; Edwards Valve; TAVR; VARC; stroke.

Publication types

  • Meta-Analysis
  • Review
  • Systematic Review

MeSH terms

  • Aortic Valve Stenosis / complications
  • Aortic Valve Stenosis / surgery*
  • Cardiac Catheterization*
  • Global Health
  • Heart Valve Prosthesis Implantation / methods*
  • Humans
  • Incidence
  • Prosthesis Design
  • Risk Assessment*
  • Stroke* / epidemiology
  • Stroke* / etiology
  • Stroke* / prevention & control
  • Treatment Outcome