[Dacron-EXS prosthesis in axillo-femoral bypass]

Minerva Chir. 1989 Nov 15;44(21):2237-9.
[Article in Italian]

Abstract

Twenty-eight axillary by-pass were performed in 27 patients using a dacron externally supported prosthesis. This group of patients has been compared with two other groups in which a dacron knitted (20 p.) or a PTFE (55 p.) prosthesis were implanted. A three years patency has been respectively: 66.6% (EXS), 57.7 (PTFE), 45.5 (Knitted Velour).

Publication types

  • Comparative Study
  • English Abstract

MeSH terms

  • Aged
  • Anastomosis, Surgical
  • Axillary Artery / surgery*
  • Blood Vessel Prosthesis*
  • Female
  • Femoral Artery / surgery*
  • Follow-Up Studies
  • Humans
  • Male
  • Polyethylene Terephthalates
  • Polytetrafluoroethylene
  • Vascular Patency*

Substances

  • Polyethylene Terephthalates
  • Polytetrafluoroethylene