Background: Reliable tools for patient selection are critical for clinical drug trials.
Aim: To evaluate a consensus-based, standardised magnetic resonance enterography (MRE) protocol for selecting patients for inclusion in Crohn's disease (CD) multicenter clinical trials.
Methods: This study recruited 20 patients [Crohn's Disease Activity Index (CDAI) scores: <150 (n = 8); 150-220 (n = 4); 220-450 (n = 8)], to undergo ileocolonoscopy and two MREs (with and without colonic contrast) within a 14-day period. Procedures were scored centrally using, Magnetic Resonance Index of Activity (MaRIA), and both Crohn's Disease Endoscopic Index of Severity (CDEIS) and Simplified Endoscopic Score (SES-CD).
Results: 37 MREs were acquired. Both MREs were evaluable in 16 patients for calculation of test-retest and inter-reader reliability scores. The MaRIA scores for the terminal ileum had excellent test-retest and inter-reader reliability, with correlations >0.9. The proximal ileum showed strong within-reader agreement (0.90-0.96), and fair between-reader agreement (0.59-0.72). MRE procedures were tolerable. MaRIA scores correlated with CDEIS and SES-CD (0.63 and 0.71), but not with CDAI (0.34). MRE identified 3 patients with intra-abdominal complications, who would otherwise have been included in clinical trials. Furthermore, both MRE and ileocolonoscopy identified active bowel wall inflammation in 2 patients with CDAI <150, and none in 1 patient with CDAI > 220. Data quality was good/excellent in 85% of scans, and fair or better in 96%.
Conclusions: Magnetic resonance enterography of high-quality and reproducibility was feasible in a global multi- centre setting, with evidence for improved selectivity over CDAI and ileocolonoscopy in identifying appropriate CD patients for inclusion in therapeutic intervention trials.
© 2015 John Wiley & Sons Ltd.