Accuracy of Dual Phase Single-Photon Emission Computed Tomography/Computed Tomography in Primary Hyperparathyroidism: Correlation With Serum Parathyroid Hormone Levels

Can Assoc Radiol J. 2016 May;67(2):115-21. doi: 10.1016/j.carj.2015.06.002. Epub 2015 Dec 11.

Abstract

Purpose: The objectives of this study were: 1) to determine the accuracy of dual-phase (99m)Tc -methoxyisobutylisonitrile (MIBI) with single-photon emission computed tomography/computed tomography (SPECT/CT) for the preoperative localization of parathyroid adenomas in the setting of primary hyperparathyroidism; 2) to determine the accuracy of localization for ectopic glands; and 3) to assess the relationship between accuracy and serum parathyroid hormone (PTH) levels.

Methods: Eighty-eight patients who underwent (99m)Tc-MIBI SPECT/CT imaging for primary hyperparathyroidism at our institution over a 27-month period were retrospectively assessed. The preoperative SPECT/CT results were compared to intraoperative findings (within 1 year of imaging). The relationship between serum PTH level (within 3 months) and SPECT/CT accuracy was then evaluated.

Results: Accuracy indices for the retrothyroid subgroup were sensitivity 86.7%, specificity 96.4%, positive predictive value 98.1%, negative predictive value 77.1%, and accuracy 89.8%. Accuracy indices for ectopic parathyroid adenomas were sensitivity 81.5%, specificity 100%, positive predictive value 100%, negative predictive value 92.4%, and accuracy 94.3%. For the overall group, SPECT/CT demonstrated a sensitivity of 85.1% and a PPV of 98.7%. SPECT/CT correctly identified the abnormal parathyroid gland in 60% of patients with a normal serum PTH (<6.9 pmol/L), 73% between 6.9-9.9 pmol/L, 86% between 10.0-14.9 pmol/L, 100% between 15.0-19.9 pmol/L, 88% between 20.0-24.5 pmol/L, and 100% of patients with a PTH greater than 25.0 pmol/L.

Conclusions: Dual-phase (99m)Tc- MIBI with SPECT/CT is an accurate and reliable means to correctly localize both retrothyroid and ectopic parathyroid adenomas for the purpose of surgical planning. The accuracy of SPECT/CT increases with increasing serum PTH levels.

Keywords: (99m)Tc-methoxyisobutylisonitrile; Parathyroid adenoma; Parathyroid hormone; Primary hyperparathyroidism; Single-photon emission computed tomography/computed tomography.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Female
  • Humans
  • Hyperparathyroidism, Primary / blood*
  • Hyperparathyroidism, Primary / diagnostic imaging*
  • Male
  • Middle Aged
  • Parathyroid Glands / diagnostic imaging
  • Parathyroid Hormone / blood*
  • Reproducibility of Results
  • Retrospective Studies
  • Sensitivity and Specificity
  • Single Photon Emission Computed Tomography Computed Tomography*
  • Young Adult

Substances

  • Parathyroid Hormone