Effect of Dexmedetomidine on Heart Rate-Corrected QT and Tpeak-Tend Intervals During Robot-Assisted Laparoscopic Prostatectomy With Steep Trendelenburg Position: A Prospective, Randomized, Double-Blinded, Controlled Study

Medicine (Baltimore). 2016 May;95(19):e3645. doi: 10.1097/MD.0000000000003645.

Abstract

Intraperitoneal insufflation of carbon dioxide may affect the sympathetic activity that leads to changes in ventricular repolarization. This in turn can result in changes of heart rate-corrected QT (QTc) interval and Tpeak-Tend (Tp-e) interval. Dexmedetomidine is a highly selective α2-receptor agonist and has potential antiarrhythmic properties. This prospective, randomized, double-blinded, controlled study evaluated the effects of dexmedetomidine administration on QTc and Tp-e intervals during robot-assisted laparoscopic prostatectomy with steep Trendelenburg position.Fifty patients scheduled for robot-assisted laparoscopic prostatectomy randomly received either a continuous infusion of dexmedetomidine at a rate of 0.3 μg/kg/hour, from anesthetic induction until the end of the Trendelenburg position (dexmedetomidine group; n = 25), or the same volume of normal saline (control group; n = 25). Anesthesia was maintained with sevoflurane and remifentanil. The primary and secondary goals were to evaluate the effect of dexmedetomidine on the QTc and Tp-e interval changes. Mean arterial pressure, heart rate, end-tidal CO2, and end-tidal sevoflurane concentrations were assessed as well.Forty-seven patients (94%) completed the study. Dexmedetomidine significantly attenuated QTc interval prolongation and reduced the Tp-e interval, even though the baseline values of the QTc and Tp-e intervals were similar between the 2 groups (PGroup × Time = 0.001 and 0.014, respectively). Twenty-two patients (96%) in the control group and 13 (54%) in the dexmedetomidine group had QTc interval prolongation of >20 ms from the baseline value during surgery (P = 0.001). The maximum QTc interval prolongation from the baseline value during surgery was 46 ± 21 ms in the control group and 24 ± 21 ms in the dexmedetomidine group (mean ± SD, P = 0.001). Mean arterial pressure and heart rate were comparable between the groups.Continuous infusion of dexmedetomidine at a rate of 0.3 μg/kg/hour significantly attenuated the QTc interval prolongation induced by CO2 pneumoperitoneum with steep Trendelenburg position. Furthermore, dexmedetomidine reduced the Tp-e interval. Thus, dexmedetomidine administration may be effective for patients who are susceptible to the development of ventricular arrhythmia during robot-assisted laparoscopic prostatectomy.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Dexmedetomidine / pharmacology*
  • Double-Blind Method
  • Head-Down Tilt
  • Heart Conduction System / drug effects*
  • Heart Rate / drug effects*
  • Humans
  • Hypnotics and Sedatives / pharmacology*
  • Intraoperative Care / methods
  • Laparoscopy / methods
  • Male
  • Middle Aged
  • Prospective Studies
  • Prostatectomy / methods*
  • Robotic Surgical Procedures / methods

Substances

  • Hypnotics and Sedatives
  • Dexmedetomidine