Abstract

Objectives: This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS.

Background: To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS).

Methods: Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year.

Results: A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization.

Conclusions: Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices.

Keywords: bare-metal stent(s); bioresorbable vascular scaffolds; drug-eluting stent(s); percutaneous coronary intervention; stent thrombosis.

Publication types

  • Meta-Analysis
  • Review
  • Systematic Review

MeSH terms

  • Absorbable Implants*
  • Bayes Theorem
  • Coronary Disease / mortality
  • Coronary Disease / therapy*
  • Coronary Thrombosis / etiology
  • Coronary Thrombosis / mortality
  • Coronary Thrombosis / prevention & control*
  • Drug-Eluting Stents*
  • Humans
  • Markov Chains
  • Monte Carlo Method
  • Network Meta-Analysis
  • Odds Ratio
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Percutaneous Coronary Intervention / mortality
  • Prosthesis Design
  • Randomized Controlled Trials as Topic
  • Risk Assessment
  • Risk Factors
  • Time Factors
  • Treatment Outcome