Purpose: To explore the feasibility of parotid spin-lattice relaxation time in the rotating frame (T1ρ) MR imaging in the diagnosis of Sjögren's syndrome (SS) without morphological changes of the parotid glands.
Materials and methods: The study enrolled 32 consecutive SS patients without morphological changes of parotid glands and 32 age- and gender-matched healthy volunteers who underwent parotid 3.0 Tesla MR imaging, including T1ρ sequences. Follow-up imaging was performed at 3 months. T1 signal intensities and T1ρ values of bilateral parotid glands were compared using paired samples t-test. Parotid T1 signal intensities and T1ρ values were compared using two independent samples t-test. Diagnostic performance of the parotid T1ρ values was evaluated by receiver operating characteristic analysis. The intraclass correlation coefficient (ICC) was calculated to evaluate the reproducibility of parotid T1ρ measurements.
Results: There were no significant differences of T1 signal intensities and T1ρ values between bilateral parotid glands in SS patients and healthy volunteers (P = 0.170, 0.886 and 0.942, 0.229). The parotid T1ρ values of SS patients (96.47 ± 15.38 ms) were significantly higher than those of healthy volunteers (84.25 ± 6.11 ms) (P < 0.001), while there were no significant differences of T1 signal intensities between SS patients and healthy volunteers (P = 0.655). With a cutoff value of 88.02 ms, the sensitivity and specificity of the parotid T1ρ value was 75.0% and 100.0% in the diagnosis of SS. The reproducibility of parotid T1ρ measurement was excellent (ICC: 0.934-0.995).
Conclusion: Parotid T1ρ MR imaging held a potential role in diagnosing SS without morphological changes of parotid glands.
Level of evidence: 2 J. Magn. Reson. Imaging 2017;45:1005-1012.
Keywords: Sjögren's syndrome; T1ρ MR imaging; morphological changes; parotid glands; signal changes.
© 2016 International Society for Magnetic Resonance in Medicine.