A huge saccular aortic aneurysm compressing right coronary artery 7 years after aortic valve replacement due to bicuspid aortic valve insufficiency: A rare case report

Medicine (Baltimore). 2016 Oct;95(40):e4860. doi: 10.1097/MD.0000000000004860.

Abstract

Background: In a patient underwent aortic valve replacement (AVR) due to bicuspid aortic valve (BAV) insufficiency without marked dilation of ascending aorta, the development of delayed-typed aneurysmal complication of ascending aorta has been often reported because the dilated aorta tends to grow insidiously with age.

Case summary: A 58-year-old man who underwent AVR with mechanical valve due to severe aortic regurgitation secondary to BAV 7 years previously presented with exertional chest discomfort for 1 year. An echocardiography showed a well-functioning mechanical aortic valve without any significant abnormal findings. Cardiac multidetector computed tomography (MDCT) revealed a huge saccular aortic root aneurysm (79.7 mm × 72.8 mm in size) compressing the proximal right coronary artery resulting in ∼90% eccentric diffuse luminal narrowing. The patient subsequently underwent open-heart surgery with resection of the ascending aortic aneurysmal sac and consecutive ascending aorta and hemi-arch replacement using a graft.

Conclusion: After successful AVR in the patient with BAV insufficiency and mildly dilated ascending aorta, a regular aortic imaging such as cardiac MDCT with aortography would be helpful to monitor the morphology and size of ascending aorta and related complications to guide future management.

Publication types

  • Case Reports

MeSH terms

  • Aortic Aneurysm / diagnostic imaging*
  • Aortic Aneurysm / etiology*
  • Aortic Aneurysm / surgery
  • Aortic Valve / abnormalities*
  • Aortic Valve / surgery
  • Aortography
  • Bicuspid Aortic Valve Disease
  • Coronary Angiography
  • Coronary Stenosis / diagnostic imaging*
  • Coronary Stenosis / etiology
  • Coronary Stenosis / surgery
  • Heart Valve Diseases / complications*
  • Heart Valve Diseases / surgery
  • Heart Valve Prosthesis Implantation*
  • Humans
  • Male
  • Middle Aged
  • Multidetector Computed Tomography
  • Postoperative Complications / diagnostic imaging*
  • Postoperative Complications / etiology
  • Postoperative Complications / surgery
  • Time Factors