Long-term clinical outcome after implantation of the self-expandable STENTYS stent in a large, multicenter cohort

Coron Artery Dis. 2017 Nov;28(7):588-596. doi: 10.1097/MCA.0000000000000533.

Abstract

Objective: The objective of the study was to retrospectively evaluate the long-term clinical outcome after implantation of the self-expandable (SE) STENTYS stent in a large multicenter cohort.

Background: Incomplete stent apposition is known to cause higher rates of myocardial infarction (MI) and stent thrombosis. Because of its self-expanding features, the SE STENTYS stent adapts to the vessel wall and is therefore expected to minimize malapposition and therefore the rates of MI and stent thrombosis.

Patients and methods: Treatment with a total of 351 SE coronary stents was attempted in 314 patients of a cohort from three German institutions between 2011 and 2015. Technical success was achieved with 331/351 (94%) stents. Patients treated successfully with SE stents (n=298) were followed up using the primary outcome measure of target lesion failure (TLF), a combined endpoint of cardiac mortality, recurrent target vessel MI, acute stent thrombosis, and clinically driven target lesion revascularization. Follow-up was complete in 268/298 (90%) patients with a median follow-up period of 2.5 (interquartile range: 1.4-3.3) years.

Results: TLF occurred in 54/298 (18%) patients. Event rates were 7.5% for cardiac mortality, 11.6% for target vessel MI, and 5.2% for clinically driven target lesion revascularization. Acute stent thrombosis occurred in 2/298 (0.7%). Overall, stent thrombosis had an incidence of 2.6% within the follow-up period. ST-elevation MI at baseline (P=0.02) and a dual antiplatelet therapy with clopidogrel for only 6 months (P=0.04) were the only clinical factors linked to the absence of TLF.

Conclusion: Technical success of SE coronary stent implantation in an all-comer cohort of patients was high, although the rate of TLF and stent thrombosis during long-term follow-up was also relatively high.

Publication types

  • Multicenter Study

MeSH terms

  • Acute Coronary Syndrome / diagnostic imaging
  • Acute Coronary Syndrome / mortality
  • Acute Coronary Syndrome / therapy*
  • Aged
  • Alloys
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / therapy*
  • Coronary Thrombosis / epidemiology
  • Female
  • Germany / epidemiology
  • Humans
  • Incidence
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Non-ST Elevated Myocardial Infarction / diagnostic imaging
  • Non-ST Elevated Myocardial Infarction / mortality
  • Non-ST Elevated Myocardial Infarction / therapy*
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Percutaneous Coronary Intervention / mortality
  • Proportional Hazards Models
  • Prosthesis Design
  • Quality of Life
  • Recurrence
  • Retrospective Studies
  • Risk Factors
  • ST Elevation Myocardial Infarction / diagnostic imaging
  • ST Elevation Myocardial Infarction / mortality
  • ST Elevation Myocardial Infarction / therapy*
  • Self Expandable Metallic Stents*
  • Time Factors
  • Treatment Outcome

Substances

  • Alloys
  • nitinol