Successful percutaneous trans-catheter treatment of left ventricular assist device outflow graft stenosis with a covered stent

ESC Heart Fail. 2015 Jun;2(2):100-102. doi: 10.1002/ehf2.12030. Epub 2015 Apr 30.

Abstract

Left ventricular assist devices improve survival in patients with advanced heart failure but can be associated with significant complication including infection, pump thrombosis, and de novo severe aortic insufficiency. Outflow graft stenosis is a much more rare complication, but one with significant hemodynamic consequences. Surgical repair is often necessary, but many patients are too high risk for further surgical intervention. We describe the first case of left ventricular assist device outflow graft stenosis treated with percutaneous trans-catheter placement of a covered stent.

Keywords: Left ventricular assist device; Percutaneous repair; Stent.