Abstract
We report the management of three iatrogenic injuries involving the aortic valve, left circumflex artery, and left ventricular outflow tract, that occurred during a re-operative mitral valve replacement.
© 2017 Wiley Periodicals, Inc.
MeSH terms
-
Aged
-
Aortic Valve / injuries*
-
Bioprosthesis
-
Coronary Vessels / injuries*
-
Diabetes Mellitus
-
Diagnostic Imaging
-
Female
-
Heart Valve Prosthesis
-
Heart Valve Prosthesis Implantation / adverse effects*
-
Heart Valve Prosthesis Implantation / methods*
-
Heart Ventricles / injuries*
-
Humans
-
Hypertension
-
Iatrogenic Disease
-
Intraoperative Complications / etiology*
-
Mitral Valve / diagnostic imaging
-
Mitral Valve / surgery*
-
Mitral Valve Insufficiency / diagnostic imaging
-
Mitral Valve Insufficiency / surgery*
-
Reoperation*
-
Stroke