Background: Patients with severe and moderate haemophilia A are treated prophylactically with factor VIII (FVIII) concentrate. Individualization of prophylaxis can be achieved by pharmacokinetic (PK)-guided dosing.
Aim: In this study, the performance of three PK tools (myPKFiT, Web-Accessible Population Pharmacokinetic Service-Hemophilia [WAPPS] and NONMEM) is compared.
Methods: In 39 patients, with severe or moderate haemophilia A, blood samples were collected 4, 24 and 48 hours after administration of 50 IU kg-1 of recombinant FVIII (Advate [n = 30] or Kogenate [n = 9]). FVIII dose, FVIII activity and patient characteristics were entered into the three PK tools. Obtained PK parameters and dosing advises were compared.
Results: myPKFiT provided PK parameters for 24 of 30 patients receiving Advate, whereas WAPPS and NONMEM provided estimates for all patients. Half-life was different among the three methods: medians were 12.6 hours (n = 24), 11.2 hours (n = 30) and 13.0 hours (n = 30) for myPKFiT, WAPPS and NONMEM (p < 0.001), respectively. To maintain a FVIII trough level of 0.01 IU mL-1 after 48 hours, doses for myPKFiT and NONMEM were 15.1 and 11.0 IU kg-1 (p < 0.01, n = 11) and for WAPPS and NONMEM were 9.0 and 8.0 IU kg-1 (p < 0.01, n = 23), respectively. In nine patients receiving Kogenate, WAPPS and NONMEM produced different PK-parameter estimates; half-life was 15.0 and 12.3 hours and time to 0.05 IU mL-1 was 69.2 and 60.8 hours, respectively (p < 0.01, n = 9). However, recommended doses to obtain these levels were not different.
Conclusion: The three evaluated PK tools produced different PK parameters and doses for recombinant FVIII. Haematologists should be aware that recommended doses may be influenced by the choice of PK tool.
Schattauer GmbH Stuttgart.