Background: Acute respiratory failure (ARF) is a common and life-threatening medical emergency. Standard prehospital management involves controlled oxygen therapy and disease-specific ancillary treatments. Continuous positive airway pressure (CPAP) is a potentially beneficial alternative treatment that could be delivered by emergency medical services. However, it is uncertain whether this treatment could work effectively in United Kingdom National Health Service (NHS) ambulance services and if it represents value for money.
Methods: An individual patient randomised controlled external pilot trial will be conducted comparing prehospital CPAP to standard oxygen therapy for ARF. Adults presenting to ambulance service clinicians will be eligible if they have respiratory distress with peripheral oxygen saturation below British Thoracic Society (BTS) target levels, despite titrated supplemental oxygen. Enrolled patients will be allocated (1:1 simple randomisation) to prehospital CPAP (O_two system) or standard oxygen therapy using identical sealed boxes. Feasibility outcomes will include incidence of recruited eligible patients, number of erroneously recruited patients and proportion of cases adhering to allocation schedule and treatment, followed up at 30 days and with complete data collection. Effectiveness outcomes will comprise survival at 30 days (definitive trial primary end point), endotracheal intubation, admission to critical care, length of hospital stay, visual analogue scale (VAS) dyspnoea score, EQ-5D-5L and health care resource use at 30 days. The cost-effectiveness of CPAP, and of conducting a definitive trial, will be evaluated by updating an existing economic model. The trial aims to recruit 120 patients over 12 months from four regional ambulance hubs within the West Midlands Ambulance Service (WMAS). This sample size will allow estimation of feasibility outcomes with a precision of < 5%. Feasibility and effectiveness outcomes will be reported descriptively for the whole trial population, and each trial arm, together with their 95% confidence intervals.
Discussion: This study will determine if it is feasible, acceptable and cost-effective to undertake a full-scale trial comparing CPAP and standard oxygen treatment, delivered by ambulance service clinicians for ARF. This will inform NHS practice and prevent inappropriate prehospital CPAP adoption on the basis of limited evidence and at a potentially substantial cost.
Trial registration: ISRCTN12048261. Registered on 30 August 2017. http://www.isrctn.com/ISRCTN12048261.
Keywords: Acute respiratory failure; Continuous positive airways pressure; Emergency medical services; Prehospital.