Noninvasive determination of human cortisol and dehydroepiandrosterone sulfate using liquid chromatography-tandem mass spectrometry

Anal Bioanal Chem. 2019 Feb;411(6):1203-1210. doi: 10.1007/s00216-018-1549-x. Epub 2019 Jan 5.

Abstract

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) for measurements of steroids in human saliva has garnered increased interest in the area of clinical psychoneuroendocrinological research. However, performance characteristics of LC-MS/MS methods for the analysis of steroids in saliva are limited. Human saliva samples were collected via passive drool. Cortisol and dehydroepiandrosterone sulfate (DHEA-S) in the samples were extracted together, resolved on a C18-A column, and analyzed using tandem mass spectrometry. The LC-MS/MS method had limits of quantitation of 0.03 and 0.06 ng/mL for DHEA-S and cortisol, respectively. Method evaluations showed coefficient variation (%CV) of inter-assay ranging 4.6-17.9% for DHEA-S and cortisol, recoveries of 102.4-109.5% for DHEA-S and 94.6-98.3% for cortisol, and assay linearity with R2 = 0.9964 for DHEA-S (1.0-25.0 ng/mL) and R2 = 0.997 (1.0-25.0 ng/mL) for cortisol. No cross contamination among samples was observed. Human saliva showed 20% and 18% ion enhancement effect for DHEA-S and cortisol assay, respectively. No interference by ten common steroids was detected. Regression analysis of method comparisons with laboratory-developed test (LDT) method revealed R2 = 0.9688 (LC-MS/MS = 0.9665 LDT-LC-MS/MS - 0.7355) for cortisol, and R2 = 0.9039 (LC-MS/MS = 1.0173 LDT-LC-MS/MS + 3.6797) for DHEA-S. Reference ranges for young adults were determined to be 0.3-5.9 ng/mL for females and 0.1-5.6 ng/mL for males for salivary cortisol, and 0.6-7.4 ng/mL for females and 0.6-10.1 ng/mL for males for salivary DHEA-S. An LC-MS/MS method for quantifying cortisol and DHEA-S in human saliva was developed and validated for clinical and psychoneuroendocrinological research that require noninvasive means of measuring these hormones.

Keywords: Cortisol; DHEA-S; Dehydroepiandrosterone sulfate; Mass spectrometry; Saliva.

Publication types

  • Evaluation Study

MeSH terms

  • Adolescent
  • Adult
  • Chromatography, Liquid / methods
  • Dehydroepiandrosterone Sulfate / analysis*
  • Female
  • Humans
  • Hydrocortisone / analysis*
  • Limit of Detection
  • Male
  • Reference Values
  • Saliva / chemistry*
  • Tandem Mass Spectrometry / methods*
  • Young Adult

Substances

  • Dehydroepiandrosterone Sulfate
  • Hydrocortisone