The Safety and Feasibility of Same-Day Discharge After Implantation of MICRA Transcatheter Leadless Pacemaker System

J Atr Fibrillation. 2019 Jun 30;12(1):2153. doi: 10.4022/jafib.2153. eCollection 2019 Jun.

Abstract

Background: Data suggests that same day discharge after implantation of trans-venous pacemakers is safe and feasible. We sought to determine whether same day discharge was feasible and safe following implantation of Medtronic MICRA leadless pacemakers.

Methods: We retrospectively identified all patients undergoing MICRA placement at our institution between April 2014 to August 2018 (n=167). Patients were stratified into two groups: those discharged on the same day as their procedure (SD, n=25), and those observed for at least one night in the hospital (HD, n=142). The primary endpoint included a composite of major complications including: access site complications, new pericardial effusion, device dislodgement, and need for device revision up to approximately 45 days of follow up.

Results: SD and HD had similar age (75±13 vs. 75±13 years, p=0.923), prevalence of male sex (49 vs. 44%, p=0.669), and frequency of high-grade heart block as an indication for pacing (38 vs. 32%, p=0.596). There were more Caucasians in the SD group (72 vs. 66%, p=0.038). The rate of the composite endpoint was statistically non-significantly higher in the HD group (3.5% vs. 0.0%, p=1.00). The rates of each individual components comprising the composite endpoint were similar between groups.

Conclusions: Our data suggest that in appropriately selected patients, same day discharge can occur safely following Micra leadless pacemaker implantation.

Keywords: Discharge; MICRA; Pacemaker.