Routine Fracture Fixation for a Periprosthetic Hip Fracture Below Birmingham Hip Resurfacing: A Case Report

JBJS Case Connect. 2020 Jul-Sep;10(3):e19.00540. doi: 10.2106/JBJS.CC.19.00540.

Abstract

Case: We present a case of a 56-year-old man who sustained a basal cervical periprosthetic fracture around a well-fixed metal-on-metal hip resurfacing arthroplasty (MoMHRA). Although several fixation methods have been described, there seems to be no consensus about the optimal fixation method for fractures around MoMHRAs. This fracture could be regarded as a Vancouver type-B1 or -C periprosthetic fracture, so we successfully treated our patient in a standard way with a dynamic hip screw (DHS) and one cannulated hip screw.

Conclusion: We describe DHS fixation as a successful treatment option for periprosthetic hip fractures around well-fixed MoMHRA.

Publication types

  • Case Reports

MeSH terms

  • Fracture Fixation, Internal / methods*
  • Hip Fractures / surgery*
  • Humans
  • Male
  • Middle Aged
  • Periprosthetic Fractures / surgery*