Observer Performance for Detection of Pulmonary Nodules at Chest CT over a Large Range of Radiation Dose Levels

Radiology. 2020 Dec;297(3):699-707. doi: 10.1148/radiol.2020200969. Epub 2020 Sep 29.

Abstract

Background There is a wide variation in radiation dose levels that can be used with chest CT in order to detect indeterminate pulmonary nodules. Purpose To compare the performance of lower-radiation-dose chest CT with that of routine dose in the detection of indeterminate pulmonary nodules 5 mm or greater. Materials and Methods In this retrospective study, CT projection data from 83 routine-dose chest CT examinations performed in 83 patients (120 kV, 70 quality reference mAs [QRM]) were collected between November 2013 and April 2014. Reference indeterminate pulmonary nodules were identified by two nonreader thoracic radiologists. By using validated noise insertion, five lower-dose data sets were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR; 30 QRM with FBP, 10 QRM with IR, 5 QRM with FBP, 5 QRM with IR, and 2.5 QRM with IR). Three thoracic radiologists circled pulmonary nodules, rating confidence that the nodule was a 5-mm-or-greater indeterminate pulmonary nodule, and graded image quality. Analysis was performed on a per-nodule basis by using jackknife alternative free-response receiver operating characteristic figure of merit (FOM) and noninferiority limit of -0.10. Results There were 66 indeterminate pulmonary nodules (mean size, 8.6 mm ± 3.4 [standard deviation]; 21 part-solid nodules) in 42 patients (mean age, 51 years ± 17; 21 men and 21 women). Compared with the FOM for routine-dose CT (size-specific dose estimate, 6.5 mGy ± 1.8; FOM, 0.86 [95% confidence interval: 0.80, 0.91]), FOM was noninferior for all lower-dose configurations except for 2.5 QRM with IR. The sensitivity for subsolid nodules at 70 QRM was 60% (range, 48%-72%) and was significantly worse at a dose of 5 QRM and lower, whether or not IR was used (P < .05). Diagnostic image quality decreased with decreasing dose (P < .001) and was better with IR at 5 QRM (P < .05). Conclusion CT images reconstructed at dose levels down to 10 quality reference mAs (size-specific dose estimate, 0.9 mGy) had noninferior performance compared with routine dose in depicting pulmonary nodules. Iterative reconstruction improved subjective image quality but not performance at low dose levels. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by White and Kazerooni in this issue.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Case-Control Studies
  • Female
  • Humans
  • Lung Neoplasms / diagnostic imaging*
  • Male
  • Middle Aged
  • Multiple Pulmonary Nodules / diagnostic imaging
  • Observer Variation
  • Radiation Dosage*
  • Radiographic Image Interpretation, Computer-Assisted
  • Radiography, Thoracic
  • Retrospective Studies
  • Solitary Pulmonary Nodule / diagnostic imaging
  • Tomography, X-Ray Computed / methods*