Balloon enteroscopy-assisted endoscopic retrograde cholangiography (BEA-ERC) is useful and feasible in adults with pancreatobiliary diseases, but its efficacy and safety have not been established in pediatric patients. We compared the success rate and safety of BEA-ERC between adults and pediatric patients. This single-center retrospective study reviewed 348 patients (pediatric: 57, adult: 291) with surgically altered gastrointestinal anatomies who underwent BEA-ERC for biliary disorders from January 2007 to December 2019. The success rate of reaching the anastomosis or duodenal papilla was significantly lower in pediatric patients than in adult patients (66.7% vs. 88.0%, p < 0.01). The clinical success rate was also significantly lower in pediatric patients (64.9% vs. 80.4%, p = 0.014). The rate of adverse events was significantly higher in pediatric patients than in adults (14.2% vs. 7.7%, p = 0.037). However, if the anastomotic sites were reached in pediatric patients, the treatment was highly successful (97.3%). The time of reaching target site was significantly longer in pediatric patients than in adult patients. This study shows that BEA-ERC in pediatric patients is more difficult than that in adult patients. However, in patients where the balloon enteroscope was advanced to the anastomosis, clinical outcomes comparable to those in adults can be achieved.
Keywords: balloon enteroscopy-assisted endoscopic retrograde cholangiography; double-balloon enteroscopy; surgically altered gastrointestinal anatomy.