Purpose: This feasibility study evaluated the intra-fractional prostate motion using an ultrasound image-guided system during step and shoot intensity-modulated radiation therapy (SS-IMRT) and volumetric modulated arc therapy (VMAT). Moreover, the internal margins (IMs) using different margin formulas were calculated.
Methods: Fourteen consecutive patients with prostate cancer who underwent SS-IMRT (n = 5) or VMAT (n = 9) between March 2019 and April 2020 were considered. The intra-fractional prostate motion was observed in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The displacement of the prostate was defined as the displacement from the initial position at the scanning start time, which was evaluated using the mean ± standard deviation (SD). IMs were calculated using the van Herk and restricted maximum likelihood (REML) formulas for SS-IMRT and VMAT.
Results: For SS-IMRT, the maximum displacements of the prostate motion were 0.17 ± 0.18, 0.56 ± 0.86, and 0.18 ± 0.59 mm in the SI, AP, and LR directions, respectively. For VMAT, the maximum displacements of the prostate motion were 0.19 ± 0.64, 0.22 ± 0.35, and 0.14 ± 0.37 mm in the SI, AP, and LR directions, respectively. The IMs obtained for SS-IMRT and VMAT were within 2.3 mm and 1.2 mm using the van Herk formula and within 1.2 mm and 0.8 mm using the REML formula.
Conclusions: This feasibility study confirmed that intra-fractional prostate motion was observed with SS-IMRT and VMAT using different margin formulas. The IMs should be determined according to each irradiation technique using the REML margin.
Keywords: REML formula; VMAT; internal margin for prostate; step and shoot IMRT; van Herk formula.
© 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine.