We report a patient with hereditary erythrocytosis who underwent a therapeutic phlebotomy and had a post-phlebotomy hematocrit that was higher than the pre-phlebotomy hematocrit. We could not discern a reason for this hematocrit increase after phlebotomy. Instead of performing another phlebotomy, we performed an automated red cell depletion via an apheresis instrument. This procedure is essentially a red cell exchange, but 5% albumin is used as the replacement fluid instead of red blood cells. The patient's hematocrit decreased from 80% to 39% after three consecutive daily red cell depletion procedures. We share our experience to report the unusual finding of a patient's hematocrit that increased with phlebotomy and to raise awareness of the red cell depletion procedure.
Copyright © 2022 Rushad Machhi et al.