Abstract
18 patients underwent CT-investigation with bolus injection of contrast medium 5 to 11 years after splenorenal Warren shunt. According to this investigation all patients were found to have developed hepatofugal collaterals in consequence of distal splenorenal anastomotic suction. In most cases the portal liver perfusion was maintained. These effects are not homogeneous and show variations from patient to patient.
MeSH terms
-
Adult
-
Aged
-
Collateral Circulation
-
Female
-
Follow-Up Studies
-
Hemodynamics*
-
Humans
-
Hypertension, Portal / surgery*
-
Liver Circulation
-
Male
-
Middle Aged
-
Portal System / diagnostic imaging*
-
Portal Vein / diagnostic imaging
-
Portasystemic Shunt, Surgical*
-
Postoperative Complications / diagnostic imaging
-
Renal Veins / diagnostic imaging
-
Splenic Vein / diagnostic imaging
-
Splenorenal Shunt, Surgical*
-
Tomography, X-Ray Computed*