Satisfactory results after endoscopic gluteus medius repair combined with selective gluteus maximus reflected tendon release for the treatment of a full-thickness tear of gluteus medius

Knee Surg Sports Traumatol Arthrosc. 2023 May;31(5):2038-2045. doi: 10.1007/s00167-022-07140-x. Epub 2022 Sep 6.

Abstract

Purpose: The current study aimed to report the mid-term follow-up results of endoscopic gluteus medius repair combined with a systematic release of the gluteus maximus reflected tendon.

Methods: Twenty-two patients with a symptomatic full-thickness tear of the gluteus medius tendon, as diagnosed by clinical examination and imaging (MRI), and who had a failure of conservative treatment for at least 6 months, were retrospectively enrolled for this study. An endoscopic repair of gluteus medius was performed for all patients in combination with gluteus maximus reflected tendon release according to the Polesello technique. The Visual Analogue Scale (VAS) for pain, Modified Harris Hip Score (mHHS), Lower Extremity Functional Scale (LEFS), Hip Outcome Score-Activity Daily Life (HOS-ADL), and Hip Outcome Score-Sport Specific Subscale (HOS-SSS) were administered to each patient before surgery for 6 months, 1 year, and every following year after surgery.

Results: All analysed hip scores (mHHS, LEFS, HOS-ADL, and HOS-SSS) showed statistically significant improvements between the pre-operative and post-operative values at 6 months, 1 year, and the latest follow-up appointments after surgery (p < 0.001). The mean pre-operative pain was 8.6 ± 1.0 on the VAS. After surgical treatment, the pain was significantly reduced (p < 0.001) on the VAS at 6 months (5.4 ± 1.5), 1 year (4.4 ± 1.8) and the latest follow-up control visit (3.6 ± 2.2). No patient-reported major complications (re-rupture, deep infection or neurovascular injury). Eleven (50%) patients indicated the results as excellent, 7 (32%) as good, 2 (9%) as fair, and 2 (9%) as poor.

Conclusion: The use of abductor tendon repair in combination with a systematic release of the reflected tendon of the gluteus maximus according to the Polesello technique seems to be a safe and effective endoscopic way of treating a full-thickness tear of the gluteus medius.

Level of evidence: Level IV.

Keywords: Endoscopy; Gluteus maximus reflected tendon release; Gluteus medius full-thickness tear; Hip arthroscopy; Surgical technique.

MeSH terms

  • Buttocks
  • Humans
  • Pain*
  • Retrospective Studies
  • Tenotomy*
  • Treatment Outcome