Direct comparison of two 50 W high power short duration approaches-Temperature- versus ablation index-guided radiofrequency ablation for atrial fibrillation

J Cardiovasc Electrophysiol. 2022 Dec;33(12):2517-2527. doi: 10.1111/jce.15674. Epub 2022 Sep 28.

Abstract

Introduction: Approaches applying higher energy levels for shorter periods (high power short duration, HPSD) to improve lesion formation for atrial fibrillation (AF) ablation have been introduced. This single-center study aimed to compare the efficacy, safety, and lesion formation using the novel DiamondTemp (DT) catheter or an ablation index (AI)-guided HPSD ablation protocol using a force-sensing catheter with surround-flow irrigation.

Methods: One hundred thirteen consecutive patients undergoing radiofrequency-guided catheter ablation (RFCA) for AF were included. Forty-five patients treated with the DT catheter (50 W, 9 s), were compared to 68 consecutive patients undergoing AI-guided ablation (AI anterior 550; AI posterior 400) adherent to a 50 W HPSD protocol. Procedural data and AF recurrence were evaluated.

Results: Acute procedural success was achieved in all patients (n = 113, 100%). DT-guided AF ablation was associated with a longer mean procedure duration (99.10 ± 28.30 min vs. 78.24 ± 25.55, p < .001) and more RF applications (75.24 ± 30.76 min vs. 61.27 ± 14.06, p = .019). RF duration (792.13 ± 311.23 s vs. 1035.54 ± 287.24 s, p < .001) and fluoroscopy dose (183.81 ± 178.13 vs. 295.80 ± 247.54 yGym2 , p = .013) were lower in the DT group. AI-guided HPSD was associated with a higher AF-free survival rate without reaching statistical significance (p = .088). Especially patients with PERS AF (p = .009) as well as patients with additional atrial arrhythmia substrate (p = .002) benefited from an AI-guided ablation strategy.

Conclusion: Temperature- and AI- controlled HPSD RFCA using 50 W was safe and effective. AI-guided HPSD ablation seems to be associated with shorter procedure durations and fewer RF applications. Particularly in advanced AF, freedom from AF-recurrence may be improved using an AI-guided HPSD approach.

Keywords: 50 W; DiamondTemp; atrial fibrillation; high power short duration; novel technologies; radiofrequency ablation.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Atrial Fibrillation* / diagnosis
  • Atrial Fibrillation* / etiology
  • Atrial Fibrillation* / surgery
  • Catheter Ablation* / adverse effects
  • Catheter Ablation* / methods
  • Humans
  • Pulmonary Veins* / surgery
  • Radiofrequency Ablation*
  • Recurrence
  • Temperature
  • Treatment Outcome