Introduction: Technological advancements enabled the analyses of limited sample volumes on 1H NMR. Manual spectral profiling of the data is, however, complex, and timely.
Objective: To evaluate the performance of BAYESIL for automated identification and quantification of 1H NMR spectra of limited volume samples.
Method: Aliquots of a pooled African elephant serum sample were analyzed using standard and reduced volumes. Performance was evaluated on confidence scores, non-detects and laboratory CV.
Results: Of the 47 compounds detected, 28 had favorable performances. The approach could differentiate samples based on biological variation.
Conclusions: BAYESIL is valuable for limited sample 1H NMR data analyses.
Keywords: 1H NMR; BAYESIL; Elephant; Limited sample volume; Serum.