Background: Semipermeable membranes might be suitable for glove liners or comfort gloves in individuals with irritant contact dermatitis (ICD).
Objectives: To evaluate the effects of different glove materials on inflammation and epidermal barrier impairment after experimental skin irritation.
Methods: Nine test areas on the volar forearms of 24 healthy volunteers were irritated with sodium lauryl sulfate (1%) and afterward covered for 6 days (6 or 8 h/day) with semipermeable Sympatex (SYM), vinyl (OCC), combinations of vinyl with Sympatex (SYM/OCC) or cotton (COT/OCC), or left uncovered (CON). Up to day 10, measurements of transepidermal water loss (TEWL), erythema (a*), skin humidity (SH) and visual scoring (VS) were applied.
Results: No significant differences in skin parameters were found between COT/OCC and SYM/OCC as well as between each of the combinations and CON. SYM, COT/OCC and SYM/OCC led to better results for most skin parameters than OCC alone.
Conclusions: Occlusive material has a negative impact on skin barrier recovery and inflammation after skin irritation whereas SYM is not inferior to uncovered areas indicating good tolerability. Altogether, the data suggest that SYM is a useful alternative to COT as material for glove liners and comfort gloves in ICD patients.
Keywords: Sympatex; glove; hand eczema; irritation; liners; non-invasive measuring methods; occlusion; semipermeable.