The demand for rapid and efficient diagnostic point-of-care tests for respiratory infectious diseases has become increasingly critical in the current landscape. The emphasis on accessibility has been underscored over the past year, making it crucial to have biological components that exhibit fast and accurate kinetics. The foundation for precise, swift, and effective testing relies on the availability of highly responsive biological agents. Two published aptamer DNA sequences designated Song and MSA52 and their truncated internal stem-loop structures were studied for their potential to serve as aptamer beacons for rapid COVID detection. The candidate beacons were covalently labeled with Atto 633 dye attached to their 5' ends and Iowa Black quencher attached to their 3' ends. The whole aptamer structures exhibited the greatest fluorescence signal intensities and higher fluorescence background than their truncated internal stem-loop beacon structures suggesting that the distance between fluorophores and quenchers was greater for the whole aptamer beacon candidates versus the isolated stem-loop structures. Beacon candidates were tested against two heat- or gamma radiation-killed SARS-CoV-2 Washington 1/2020 virus samples and three different COVID spike (S) proteins to test their effectiveness. Despite the higher background fluorescence, the whole aptamer beacons showed better signal-to-noise ratios and were selected for further investigation. Limit of detection (LOD) studies revealed that both the whole Song and whole MSA52 aptamer beacon candidates had a LOD of 9.61 × 103 genome equivalents in phosphate-buffered saline using the red channel of a Promega Quantus™ fluorometer which correlated well with confirmatory spectrofluorometry. Cross-reactivity studies using numerous COVID variants, related coronaviruses, and other common respiratory pathogens suggested greater COVID selectivity for the whole MSA52 versus the whole Song aptamer beacon candidate, indicating promise for specific COVID detection. Importantly, both whole aptamer beacon candidates exhibited very rapid "bind and detect" fluorescence increases within the first 1-2 min of mixing the beacons with killed SARS-CoV-2 viruses in 100 µl samples. Overall, this work illustrates the strong potential for aptamer beacons for rapid, on-site detection and presumptive diagnosis of COVID in breath condensates or other small liquid samples. This research highlights the strong potential of aptamer beacons for addressing the need for fast and convenient diagnostic tools in global health contexts, especially in resource-limited settings.
Keywords: Aptamer; Atto 633; Beacon; COVID; Iowa Black; SARS-CoV-2; Spike protein.
© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.