Mycobacterium chimaera is a slow-growing non-tuberculous mycobacterium already known for being able to colonize cardio surgery heater-cooler units (HCUs). This study aims to describe the real magnitude of the phenomenon, providing a methodological protocol and the results of a longitudinal survey. In the period 1 January 2017-23 May 2022, over 1191 samples were collected on 35 HCUs of two different manufacturers. Among them, we identified 118 (10.3%) positive results for M. chimaera. We propose our 4-year biosurveillance experience as a practical model to minimize microbiological patients' risk, suggesting the need for new procedures and interventions for a safer and more ecological cardio surgery.
Keywords: HCUs; Mycobacterium chimaera; biosurveillance; cardio surgery; sustainable disinfection.