The MICHIGAN Procedure: Mass extraCtIon from the Heart FacIlitated by ONOCOR GlobAl embolic protectioN Device

JACC Case Rep. 2024 Aug 7;29(15):102448. doi: 10.1016/j.jaccas.2024.102448.

Abstract

Intracardiac masses present a challenging diagnostic and therapeutic dilemma and are associated with an increased risk of complications, such as embolic events and obstructive symptoms. We report a novel procedure using an ŌNŌCOR device through subclavian access that acted as a full-body protection device as well as a retrieval device.

Keywords: endovascular excision; endovascular retrieval; intracardiac mass; percutaneous intervention.

Publication types

  • Case Reports