Abstract
We report a case of complete torsion of the right lung induced by transthoracic needle biopsy. While a delay in diagnosis occurred, viability of the torsed lung was maintained, thereby allowing for effective surgical repair.
MeSH terms
-
Aged
-
Aged, 80 and over
-
Biopsy, Needle / adverse effects
-
Female
-
Humans
-
Lung / diagnostic imaging
-
Lung / pathology
-
Lung Diseases / diagnostic imaging
-
Lung Diseases / etiology*
-
Lung Diseases / surgery
-
Pneumonectomy
-
Tomography, X-Ray Computed
-
Torsion Abnormality / etiology