[Follow-up of TIPS: evaluation of signs of dysfunction with Doppler ultrasonography]

J Radiol. 1996 Dec;77(12):1201-6.
[Article in French]

Abstract

Purpose: to assess the signs of TIPS dysfunction at Doppler sonography.

Materials and methods: retrospective study of signs observed in 106 TIPS including 31 TIPS with dysfunction (portoauricular pressure gradient > 12 mmHg).

Results: the signs of TIPS dysfunction were a decrease in the mean velocity in the TIPS (for a velocity < 40 cm/sec, 90% sensitivity, 96%), a hepatopetal intrahepatic portal flow (on the right 90% sensitivity, 100% specificity, on the left 95% sensitivity, 92% specificity), a lack of cardiac modulation of the signal in the TIPS (93% sensitivity, 65% specificity), a hepatic vein flow reversal (30% sensitivity, 100% specificity), and, the only direct sign of stenosis, an increase of the mean velocity in the stenosis (42% sensitivity, 95% specificity for a velocity > or = 1 m/sec).

Conclusion: the most sensitive Doppler signs of tips dysfunction are the indirect signs of stenosis.

Publication types

  • English Abstract

MeSH terms

  • Adult
  • Aged
  • Female
  • Follow-Up Studies
  • Humans
  • Hypertension, Portal / etiology
  • Hypertension, Portal / surgery*
  • Liver Cirrhosis / complications
  • Liver Cirrhosis / surgery
  • Male
  • Middle Aged
  • Portacaval Shunt, Surgical / adverse effects*
  • Retrospective Studies
  • Sensitivity and Specificity
  • Ultrasonography, Doppler*